Filter Results By:

Products

Applications

Manufacturers

Acoustic Sources

Standard for calibrating sound level meters and sound measuring systems.

See Also: Sound Sources


Showing results: 46 - 60 of 61 items found.

  • Sound Source Localization

    HEAD acoustics GmbH

    In order to optimize product sounds, it is necessary to know the exact point of origin of a sound source. This makes possible to identify the cause of disruptive sound components and rectify these effectively, optimize sound radiation and thereby achieve the desired sound experience. The ease of use and advanced beamforming algorithms of the HEAD VISOR acoustic camera allow sound sources to be located precisely at the blink of an eye.

  • Borehole Impulsive Source Of Choice

    G-SOURCE - Sercel Group

    ​Over the years the Sercel G-SOURCE range of products has become the system of choice for advanced VSP surveys, in both offshore and onshore environments. The G-SOURCE and delta cluster combine the advantages of a powerful source and a clean acoustic performance to maximize borehole data quality.

  • Tapping Machine

    STM-1 - ECO-TECH

    Tapping Machine Type STM-1 is intended for measurements of acoustic insulation of ceiling in buildings. The unit fulfils Annex A of ISO 140-6/7. These parts of the standard require a tapping machine as a sound source for impact noise measurements. Type STM-1 is available with an optional remote control.

  • Type 1 Phantom Powered Measurement Microphone

    MK224PH - ACO Pacific, Inc.

    The MK224PH Type 1 phantom powered measurement microphone system offers a cost effective solution to acoustic measurements from phantom powered sources. Frequency Response: +/-2dB (8 Hz to 18kHz). Sensitivity: 50 mV/Pa (-26 dBV/Pa)typ. Dynamic Range 3% THD: 14dBA-145dB.

  • CAD Tool

    Sabin - Acoustic Engineering

    Sabin is a powerful CAD tool for room acoustics engineers. Based on statistical calculations, it determines the acoustical parameters of a user defined room, such as the reverberation time T60, the sound pressure level, and the RASTI as a measure of speech intelligibility. These parameters are updated dynamically, while the user is changing simulated sound sources and absorbing materials.

  • Phantom Powered Measurement Microphone System

    7052PH - ACO Pacific, Inc.

    The 7052PH Type 1.5TM phantom powered measurement microphone system offers a cost effective solution to acoustic measurements from phantom powered sources. Type 1.5TM - a superior Type 2. Frequency Response: <3 Hz to > 20kHz typ.(capsule). Sensitivity: 22 mV/Pa (-33 dBV/Pa)typ. Dynamic Range (capsule) 1% THD: <20dBA-150dBSPL (Capsule).

  • Signal Analysis

    Cross-Spectrum FFT Analysis - ZETLAB Company

    The program Cross narrow-band spectrum is used for evaluation of the interrelation between the signals’ parameters obtained from the two primary transducers installed at various parts of the controlled object. This program can be used for detection of noise source location, for sound absorption level evaluation and the researched object acoustic properties control, for evaluation of space-time distribution of the directional energy flux (Poynting vector), for the ground cross-section FR characteristic evaluation (Nakamura method), etc.

  • Event Monitoring System

    Sigma 4 - Seismic Source Co.

    Sigma 4 utilizes the “Seismic Acoustic Monitoring” seismograph node. This is the most advanced, field-proven acquisition system in the world. It works seamlessly to provide the most fully integrated source control/recorder solution.*Autonomous Operation using Internal Storage*USB External Storage for Fast Data Collection*Use internal battery option or external power connection*Internal 3C geophone or external Geophone/Seismometer/Hydrophone/Microphone*Supports standard Ethernet equipment

  • Sound Level Calibrator

    521 - ACO Pacific, Inc.

    Accepted internationally 1 kHz represents the "0 dB" reference point of A, B, C Weighting and other filters utilized in acoustic measurement. The Pistonphone - a mechanical sound source - offers a slightly higher degree of accuracy at a substantial increase in cost. In addition, the 200 or 250 Hz operating frequency is mechanically limited and not suited for measurements of filtered inputs. The 0.2 dB accuracy is quickly lost in the 0.7 to 1.5 dB tolerances acceptable for weighting filters at frequencies around 250 Hz.

  • Sound Level Calibrator

    511E - ACO Pacific, Inc.

    Accepted internationally 1 kHz represents the "0 dB" reference point of A, B, C Weighting and other filters utilized in acoustic measurement. The Pistonphone - a mechanical sound source - offers a slightly higher degree of accuracy at a substantial increase in cost. In addition, the 200 or 250 Hz operating frequency is mechanically limited and not suited for measurements of filtered inputs. The 0.2 dB accuracy is quickly lost in the 0.7 to 1.5 dB tolerances acceptable for weighting filters at frequencies around 250 Hz.

  • Directional Microphone

    MI-8100 - Ono Sokki

    MI-8100 is a shotgun type directional microphone which sharply catches the intended sound. This directional microphone is helpful for the removal of background noise in the simple sound source exploration and in abnormal sound detection. Flat frequency characteristic from 50 Hz to 20 kHz and sharp detection with high S/N ratio provide high sensitive detection of various sound coming from the specific direction. By combining the acoustic vibration monitor BL-1100, only the intended frequency or sound is focused and caught clearer.

  • Multi-frequency Ultrasound And Acoustic Imaging Camera

    SonaVuTM - SDT Ultrasound Solutions

    SonaVu™ is an acoustic imaging camera. Using its 112 ultrasound sensors and optical camera, it can detect sources of airborne ultrasound and transmit them into a visual image on its touch screen. Defects such as compressed air system leaks, compressed gas system leaks, vacuum leaks, the presence of partial discharge on electrical assets, and failed/working steam traps all create turbulence. And when there is turbulent flow present, there is airborne ultrasound. SonaVu™ makes the superhuman hearing capabilities of SDT Ultrasound Devices visible to the human eye.

  • Production Line Acoustic Test Chamber

    PLATC - Listen Inc

    The Production Line Acoustic Test Chamber from GRAS is designed for quick and qualified acoustic test of cell phones, tablet PCs, Bluetooth speaker systems etc., including frequency response, THD, Rub & Buzz and microphone test using optional sound source. The chamber has a number of connections for injecting test and control signals to the test object (DUT).Benefits include:Repeatable testing and reliable dataEasy open/close for quick and safe change of DUTFlexible test jig for easy adjustment to new DUTFlexible microphone mounting for both front/backside speakers as well as edge-mounted speakersHigh quality, high sensitive 1/4” CCP measurementmicrophone included (G.R.A.S. 46BL)Individually calibrated frequency response** Compared to reference measurement in anechoic room

  • Acoustic Analysis

    M+P International

    Noise is increasingly the subject of new regulations for the protection of human health and safety as well as for improving the environment in general. As well as sound levels, the perceived sound quality of products from washing machines to vehicles is often an important part of the customer buying decision so must be considered during product development. m+p Analyzer for noise and vibration measurement and analysis provides a full range of capability for these applications. Real-time fractional octave filters satisfy all acoustic applications from simple sound pressure, sound power for equipment legislative requirements, intensity mapping to isolate sources to sound quality metrics for product refinement.

  • 24-Bit High-Resolution Dynamic Signal Acquisition and Generation Module

    PCI-9527L - ADLINK Technology Inc.

    The PCI-9527L is a high-performance, 2-CH analog input and 2-CH analog output dynamic signal acquisition board. This board is specifically designed for audio testing, acoustic measurement, and vibration analysis applications.The ADLINK PCI-9527L features two 24-bit simultaneous sampling analog input channels. The 24-bit sigma-delta ADC provides a sampling rate up to 216 KS/s at high resolutions, making it ideal for higher bandwidth dynamic signal measurements. The sampling rate can be adjusted by setting the onboard DDS clock source to an appropriate frequency. All channels are sampled simultaneously and accept an input range from ±40 V to ±0.316 V. The PCI-9527L analog input supports software selectable AC or DC coupling and 4 mA bias current for integrated electronic piezoelectric (IEPE) sensors.

Get Help